| Manufacturer | KEMET |
|---|---|
| Manufacturer Part No | FG-R01-4ACopy |
| Manufacturer Standard Lead Time | 30 weeks |
| Order Code | 3977725 |
| Product Range | FG Fluxgate-Based Residual Current Sensor |
| Also Known As | USETR014AA0000 |
| Your Part Number | |
| Technical Datasheet |
333 In Stock
Need more?
333 Delivery in 3-4 Business Days(UK stock)
| Quantity | Price |
|---|---|
| 1+ | HK$363.170 |
Price for:Each
Minimum: 1
Multiple: 1
HK$363.17
Line Note
Added to your Order Confirmation, Invoice, and Dispatch note for this order only.
Product Information
| Manufacturer | KEMET |
|---|---|
| Manufacturer Part No | FG-R01-4ACopy |
| Manufacturer Standard Lead Time | 30 weeks |
| Order Code | 3977725 |
| Product Range | FG Fluxgate-Based Residual Current Sensor |
| Also Known As | USETR014AA0000 |
| Technical Datasheet | |
| Sensor Output Type | Analogue / Digital |
| Supply Voltage Range | 4.75V to 5.25V |
| Supply Voltage DC Min | 4.75V |
| Supply Voltage DC Max | 5.25V |
| Measured Current | AC / DC |
| Current Measuring Range DC | -50mA to 50mA |
| Accuracy | - |
| Current Measuring Range AC | -50mA to 50mA |
| Current Sensor Technology | Open Loop, Flux Gate |
| Response Time | 1s |
| Primary Current | -50mA to 50mA |
| Sensor Mounting | Through Hole |
| Operating Temperature Min | -40°C |
| Operating Temperature Max | 105°C |
| Product Range | FG Fluxgate-Based Residual Current Sensor |
| SVHC | No SVHC (04-Feb-2026) |
Product Overview
FG-R01-4A sensor is a high-sensitivity AC and DC leakage current sensor with individual open drain alarms and an analogue output for leakage current indication. In addition, its integrated test coil can be initiated by a test input to perform a functional alarm test. Typical applications include residual current sensor for in-cable control and protection devices (IC-CPD) or wallbox.
- Open-loop, fluxgate-based current sensor
- PCB mounting
- Digital output of fault detection
- Conform to IEC62752:2016/A1:2018, IEC 62955:2018 (conditional) and UL 2231-2 standards
- 3000A surge current capability
- Horizontal shape- without busbar
Technical Specifications
| Sensor Output Type | Analogue / Digital |
|---|---|
| Supply Voltage DC Min | 4.75V |
| Measured Current | AC / DC |
| Accuracy | - |
| Current Sensor Technology | Open Loop, Flux Gate |
| Primary Current | -50mA to 50mA |
| Operating Temperature Min | -40°C |
| Product Range | FG Fluxgate-Based Residual Current Sensor |
| Supply Voltage Range | 4.75V to 5.25V |
|---|---|
| Supply Voltage DC Max | 5.25V |
| Current Measuring Range DC | -50mA to 50mA |
| Current Measuring Range AC | -50mA to 50mA |
| Response Time | 1s |
| Sensor Mounting | Through Hole |
| Operating Temperature Max | 105°C |
| SVHC | No SVHC (04-Feb-2026) |
Legislation and Environmental
| Country of Origin: Country in which last significant manufacturing process was carried outCountry of Origin: | Vietnam Country in which last significant manufacturing process was carried out |
|---|---|
| Tariff No: | 90303370 |
| US ECCN: | EAR99 |
| EU ECCN: | NLR |
| RoHS Compliant: | Yes RoHS |
| RoHS Phthalates Compliant: | Yes RoHS |
| SVHC: | No SVHC (04-Feb-2026) |
| Download Product Compliance Certificate | Product Compliance Certificate |
| Weight (kg): | .02 |